Daily maintenance and care of bottle blowing machine
I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Daily maintenance is the basis for maintaining smooth operation of the machine, which can be learned by the operator observing the condition when the machine is running. In daily observation, pay attention to the operation of the machine and some conversion actions of feeding and removing bottles, etc. When some minor problems are found, stop the operation immediately and solve them quickly to reduce some unnecessary losses. Daily maintenance work is almost always carried out when the machine is running, including checking all adjustable data such as mold closing time, delayed blowing time, pre-blowing time, bottle blowing time, etc. And daily maintenance is not static, it depends on the operation and environmental conditions of the machine. Therefore, to make the machine run smoothly, when the bottle inventory is sufficient or the machine stop time is appropriate, a thorough inspection will be more conducive to the operation of the machine. The operator should pay attention to whether the oil level of the air compressor lubricating oil is sufficient.
Cleaning
Keeping the machine clean in daily
maintenance will help the machine run
smoothly. When wiping excess grease on
the machine, especially when wiping
excess grease on the connecting rod of
the mold closing mechanism, the machine
must be stopped.
Check whether the screws of each part are
loose, whether the position fixing nuts
of each group of proximity switches are
loose, and whether the conveyor belt of
the feeder is too loose.
Daily inspection and maintenance
items:
⑴ Check the quality of the bottle.
⑵ Whether the circulating water is
blocked
⑶ Listen to whether the machine has
abnormal sounds and whether the pipeline
is leaking
⑷ Check whether the fixing nuts of each
solenoid valve coil are loose
⑸ Check whether each pipeline is
bent
⑹ Discharge the drain valve of the air
storage cylinder and related equipment
(please drain every four hours in places
with high humidity)
⑺ Check whether the operating circuit
and high-pressure blowing pressure are
normal
⑻ Check whether the tension dry fixing
bolts and fiber screws are loose
⑼ Check the bottom drive travel
nut
⑽ Check whether the oil mist is
sufficient, whether the oil of the motor
speed gearbox is sufficient, and the
lubricating oil is L-DAB150 in summer
and L-DAB100 in winter.
⑾ Is the exhaust fan normal?
⑿ Check the air compressor lubricating
oil once a day